DC output voltage: 5V / 12V / 24V
Output voltage tolerance: ±2% / ±1% / ±1%
Rated output current:0-12A / 0-5A / 0-2.5A
Output Power:7W
mVp-p:120mVp-p / 120mVp-p / 150mVp-p
DC voltage adjustable range:+10, -5% / ±10% / ±10%
Start, rise, hold time:800ms,50ms,10ms/115VAC300ms,50ms,80ms/230VAC
Input Voltage range:85~264 VAC47~63 Hz;120~370VDC
AC input current:2A/115 V 1A/ 230 V
Efficiency:>85%
Impact current:Cold starting current 30A/115VAC 60A/230VAC
Leakage current:<3.5 mA/240VAC
Protection feature:
Overload protection:135%~165% automatic recovery
Overvoltage protection:115%~135% Protection mode: the mode of the automatic recovery
Environment:
Working temperature, humidity:-10℃~+60℃;20%~90 %RH
Storage temperature, humidity:-20℃~+85℃;10%~95 %RH
Resistance to shock:10~500Hz,2G 10min.
]9PGF.gif)
cle, 60min in length
Security:
Pressure resistance:Input / output: 3kVac input and ground: 1.5kVac output and ground: 0.5kvac
Insulation resistance:Input / output, input and ground, output and ground: ohms/500vdc 100m
Note:
All parameters in unspecified when, in 230VAC the input voltage is, rated load and 25 DEG C under the condition of the measured values.
Ripple and noise voltage is measured at 20MHz bandwidth oscilloscope with 12 inch double strand ends with 0.1 and 47 Mu capacitor.
3. The tolerance is set the error voltage, voltage regulation and current regulation combined.